Home » Products » 12.1 Multi Utility Patient Monitor » 12.1 Multi Utility Patient Monitor

12.1 Multi Utility Patient Monitor

12.1 Multi Utility Patient Monitor
12.1 Multi Utility Patient Monitor
Product Code : TRUSCOPE-II
Brand Name : FIRST MEDICAL SYSTEMS
Price And Quantity
  • Minimum Order Quantity
  • 1
  • Unit of Measure
  • Unit/Units
  • Price Range
  • 100000.00 - 1000000.00 INR
Product Description

We are glad to present ourselves as one of the leading manufacturers and suppliers of 12.1 Multy Utility Patient Monitor. It is a multi parameter patient monitor for ICU and recovery ward. This monitor is ergonomically designed and aesthetically enhanced with a pleasing visual appearance. The monitor has the provision of wireless or wired communication with central monitoring system. Also, 12.1 Multy Utility Patient Monitor offers remote monitoring when connected to wired central monitor. We offer this monitor at market leading prices to clients. 

Features:

  • 7 lead ECG waveform display
  • ST analysis, Arrhythmia analysis
  • 72 hours tabular and graphic trends & data storage

Features :

  • 12.1" high resolution TFT display
  • 7 lead ECG waveform display
  • ST analysis, Arrhythmia analysis
  • DIGITAL SpO2 works better even in low perfusion cases
  • Upto 66 beds network capacity to connect with CNS
  • 72 hours tabular and graphic trends & data storage
  • Drug dose calculation software
  • OXYCRG software
  • Wireless or wired communication with central monitoring system
  • Remote monitoring when connected to wired central monitor

Optional :

  • External upgradable to dual IBF: ETCO2 and Multigas [Co2, 02. N2 0 & 5AA) monitoring
  • Video output (VGA)

Specification :

  • System

    • Safety: IEC60601 approval (GB9706)
    • Dimension: 340 mm (W) X 270 mm (H) X 215 mm(D)
    • Power Supply: 90-280 V AC 50 Hz / 60 Hz
    • Alarm Indication : Visual and audible alarm
    • 500 groups of alarm events review
    • Display: 12.1" high resolution TFT
    • Application: Adult. pediatric and neonate
    • Weight: 6 Kg Approx
    • Battery Back up: 2 hrs.
  • ECG
    • Leads: I, II, III, aVR, aVL, aVF, V
    • Gains: 5 mm/mv, 10 mm/mv, 20 mm/mv, 40 mm/mv, auto
    • Input impedance: > 5 M Ω
    • Common Mode Rejeciion Ratio: 2 too dB
    • Bandwith: 05-25 Hz (monitoring mode)
      • 0.05400 Hz (diagnostic mode)
      • 1-15 Hz (surgical mode)
    • Protection: Segregation breakdown voltage 4000 VAC, 50/60 Hz.
    • Resistant to cautery protection, myoeiectricity. AC, drifting interference
    • Indication of detachment of Electrodes
    • Playback of Cardiogram
    • Scanning Speed :25 mrn/s, 50 mm/s
    • Heart Rate Range : 0-300 BPM
    • Accuracy: + BPM
  • NIBP
    • Method: Automatic oscillometric
    • Operation Modes: Single (manual). cycle (automatic), rapid (continuous)
    • Measurement: Systolic pressure/diastolic pressure] mean
    • Range Adult: 10-300 mmH
    • Pediatric: 10-235 mmHg
    • Neonate: 10-135 mmHg
    • Unit: mmHg / Kpa selectable
    • Auto Measurement: 1,2,3,5,10.l5.20.30,45,60,90 minutes, 2.4, 8, 12 hours
    • 750 groups of NIBP measuring data review
  • Respiration
    • Meihod: impedance Measurement
    • Measuring Range: 0-1 80 bpm (max. l80 bpm)
    • Alarm Limit: 0-180 bpm, upper and lower limit continuously adjustable Apnea alarm
  • SpO2 (Pulse Oximetry]
    • DIGITAL SpO2 technology
    • Range: 0-100%
    • Accuracy: +2% (70-100%)+13%(35-69%.)
    • Range of Pulse Rate: 20-250 BPM+1BPM
  • Temperature
    • Channel: 2 channels
    • Range: 050oC
    • Unit: Celsius. Fahrenheit
    • Resolution: 01oC
    • Accuracy: +0.1oC
    • Alarm Range: 0-50oC
  • IBP
    • Channel: 2 channels
    • Range: 50-300 mmHg
    • Resolution: 1 mmHg
    • Accuracy:+1 mmHg (+ l%) without probe
    • +4 mmHg(+ 2%) with probe
    • Unit: mmHg, Kpa
    • Converter Sensitivity: 5μ V/VmmHg
    • Names of Pressures: ART/ PA/ CVP / LAP / RAP / lCP
  • ETCO2
    • Method: Main stream or Side stream
    • Range:0.0-100.0 mmHg
    • Resolution: 0.1mmHg (0.01%)
    • Accuracy: 0.0-40.0 mmHg. +0.3%
    • 401-1000 mmHg. +1.0%
  • Standard configuration
    • ECG. HR, RESP. NIBP, SpO2, PR, Single TEMP, Battery
  • Option
    • 2-TEMP. 2-lBP, Recorder, ETCO2. Nellcor SpO2 and
    • Muitigas Monitoring (02. Co2, N20 & 5AA]
    • Video output ( VGA
Trade Information
  • Payment Terms
  • Others, Cheque
  • Supply Ability
  • as per requirement Per Month
  • Main Domestic Market
  • Uttar Pradesh, Punjab, Haryana, Delhi, North India
X


"We deals in Delhi, Haryana, Punjab & Uttar Pradesh"
Back to top


RFQ Request For Quotation
Get Quotes For Your Buying Requirement. Tell Suppliers What You Need.
I agree to abide by all the Terms and Conditions of tradeindia.com
FIRST MEDICAL SYSTEMS All Rights Reserved.(Terms of Use)
Developed and Managed by Infocom Network Ltd.